6. FUEL CALIBRATION
Calibration should be carried out during commissioning of the products and in
case of replacement of the pellet used. The first calibration process (installation)
must be performed by the service. Calibration procedure should be done when
the boiler is cold and not working. Before starting the calibration process, place
a bowl where you can weigh the pellet at the drop point of the pellet. (If the
supply screw is empty; Press and hold the "P3" ‘button. When pressed long, the
pellet feed will start and the pellets in your placed bowl to will come. Then press
"P3" button again and clean the bowl and perform the following operations.)
Press and hold the "P3" button. The pellet feed will then be activated and the
pellet will feed continuously for 5 minutes. At the end of this period, perform
the loading again. Weigh the pellet at the end of this 10-minute loading.
Compare the result of this weighing (Unit: Gram) in the table. Change the P05
and T03 parameter values by selecting the closest value.
Do this only if you change the pellet that you use after the initial service
and you experience a decrease in performance.
You can make the changes by following the steps below.
To change the "P05" parameter; Press "P3" and "P4" buttons for 3 seconds.
Select "tPAr" from the menu that appears. Contact your service provider for a
password. Then select "tP01" menu. With P2 (+) / P4 (-) buttons, you can reach
"P05" parameter value.
To change the "T03" parameter; Press "P3" and "P4" buttons for 3 seconds.
Select "tPAr" from the menu that appears. Contact your service provider for a
password. Then select "tP05" menu. With P2 (+) / P4 (-) buttons, you can reach
"T03" parameter value.