Operating Warnings
Assembly of İFYIL pellet stoves and fireplaces; Electrical connections and
installation should be done in accordance with the scheme.
Pellets stoves are for houses, office and internal places.
Pellets stoves must not be used in: Balcony, warehouse, bathroom etc.
Pellet stoves should not be installed in the places where people sleep. Stoves
are recommended to be avoided in places where sleep.
The stove should never be installed in the presence of flammable gases and
materials.
We do not accept any responsibility for any problem due to the outdoor
installation of
stove.
The heat requirement of the place to be installed must be calculated and the
appropriate
stove selection must be made.
Stove is not suitable for a shared (common) chimney system.
Pellets stove must be installed as close as possible to the chimney. (Chimney
connection
must be short as possible.)
Stove and chimney connector must be connected to an existing chimney or an
external double-walled chimney. (
Flue pipe inner diameter must be 1OO mm
).
Chimney height 80
cm higher than the roof ridge.
Extractor fan throw out the combustion gas and chimney easily throw out smoke.
Correct and efficient chimney system is necessary to throw out the smoke (no
reverse
smoke and throw out the smoke of stove in case of any blackout).
Chimney cleaning cap must be under chimney pipe and cleaning must be done from
here.
If the room thermostat is to be used, it should be installed 1,5 metres higher than
floor. It should not be installed in a place where temperature change and loss are
experienced.
The place where stove must be equipped with:
o
Electrical power 230V 50Hz.
o
Grounding plug.
o
If there is no ground connection it should be provided immediately.
o
Fresh air must be provided from outside.
o
Please, use the Voltage regulator for voltage fluctution.
Power supply should be used during long term power outages.
Fuel tank should not be loaded fully, 5 cm clearance should be left from the top.