Turbulator Cleaning;
1. For turbulator cleaning, the cover A (figure 9-3) must be closed.
2.Open the top cover (1), and you will see the turbulator rods. Move the
turbulator rods up and down. Again, the moves until the turbulators are cleaned
(Figure 9.1).
3.Close the top cover.
4.Then open the front cover A (figure 9-3) and ash pit cover.
5.Remove the ash pit, clean it.
6.Must do the screws off as shown in figure A. Then clean the ashes pouring
from the turbulator.
7.Close the part (A) and tighten the screws. Then reinsert the ash pit.
Combustion pot cleaning;
When cleaning the combustion pot, make sure it is completely cold. Vacuum
cleaners can be used if there is cold ash. You must check the combustion pot
daily.
Ashtray Cleaning;
Remove the ashtray (2) as shown in Figure 9-2. Clean and reinsert. You can do
this once a week.
Daily and weekly cleaning;
•
Clean the glass of your stove with a damp, soft cloth and a surface cleaner.
•
Flammable, explosive, flammable etc. When cleaning your stove. Do not use
chemicals that may pose a hazard.
• After 200 hours of operation, please call the technical service for
stove maintenance.
• Do not spray cleaner on painted parts or on fire gate seals.
The display shows the message ‘’ CLr ‘’ per 200 hours and the
system gives out an acoustic signal periodically. To stop signalling
access to Menu ‘’ rCLr ‘’ . To access this menu; Press P3 and P4
once. Use the arrow buttons (P2 / P4) to enter the ‘’ rCLr ‘’ menu
with the P3 key. Pressing the P3 key once will display the ‘’ rES ‘’
text on the display. Pressing the P3 key once again will blinks ‘’
SURE ‘’ on the display. The alarm will disappear once the P3 key is
pressed again. This is possible only in OFF state.