TG32 / TG120
Transparent Level Gauge
Edition 11/2020
D-03-B-50371-EN-01
ASSEMBLY AND OPERATING MANUAL

Other manuals for Igema TG32

Questions and Answers

  • G
    Gary RobertsJul 27, 2025
    Why is there leakage from my Igema Measuring Instruments?
    • E
      elliottkevinJul 27, 2025
      Leakage from Igema Measuring Instruments can occur due to several reasons: a break in the glass or mica, a packing set that isn't tight, or a seal that isn't tight. In such cases, it is advisable to close the shutoff valves, replace the glass/mica shield, replace the packing set or seal, and retighten screw connections. Also, slowly open the drain valve to depressurize the gauge.
  • A
    allenkimberlyAug 11, 2025
    What to do if there is no water column visible in my Igema Measuring Instruments gauge?
    • K
      Kathleen PatelAug 11, 2025
      If you cannot see the water column in your Igema Measuring Instruments gauge, it could be due to shutoff valves not being open, a blockage in the inlet or outlet pipe, or blocked connection bores within the gauge. To resolve this, close the shutoff valves, carefully open shutoff valves, clean the inlet and outlet pipes, and clean the gauge. Also, slowly open the drain valve to depressurize the gauge.

Summary

Important Safety Instructions

Symbols Used in Instructions

Explains safety symbols like Danger, Caution electrical voltage, and Caution hot.

Intended Use of the Device

Defines the device's purpose for fill level indication and compliance with PED.

Safety at Work

Covers safe access, environmental awareness, pressure checks, PPE, and load handling.

Device-Specific Safety

Safety instructions for transport, storage, servicing, and returning IGEMA devices.

Transparent Level Gauges TG32 and TG120

Assembly

Provides an exploded view and part list for assembling the level gauge.

Technical Data

Limitation of Use

Specifies maximum pressure and temperature limits for TG32 and TG120 models.

Commissioning and Maintenance

Commissioning and Maintenance Requirements

Mandates qualified personnel and outlines initial checks and testing.

Replacing Glass;Mica Shields

Guidelines for replacing glass, mica, and seals annually for safety and warranty.

Faults, Troubleshooting, and Service

Fault Analysis and Actions

Identifies common faults like leakage and no water visible, with corresponding actions.