Operation ICF18, ICF32, ICF40, ICF60, ICF80DZ
18
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW”
and “MED” (see the following table).
The battery monitor mode can be selected as follows:
1. Switch on the cooler.
2. ICF18, ICF32, ICF40, ICF60: Press the “SET” button (fig. 3 5, page 4) three
times.
3. ICF80DZ: Press the “SET” button (fig. 3 5, page 4) four times.
4. Use the “UP +” (fig. 3 7, page 4) or “DOWN –” (fig. 3 6, page 4) buttons
to select the battery monitor mode.
Display will be as follows:
Lo (LOW), Πd (MED), Hi (HIGH)
The selected mode then appears in the display for a few seconds. The dis-
play flashes several times before it returns to the current temperature.
I
6.5 Using the cooler
A
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V
10.1 V 11.2 V 11.8 V
Restart-voltage at 12 V
11.4 V 12.2 V 12.6 V
Switch-off voltage at 24 V
21.5 V 24.1 V 24.6 V
Restart voltage at 24 V
23.0 V 25.3 V 26.2 V
NOTE
When the cooler is supplied by a starter battery, select the battery
monitor mode “HIGH”. If the cooler is connected to a supply bat-
tery, the battery monitor mode “LOW” will suffice.
NOTICE! Overheating hazard
Ensure at all times that there is sufficient ventilation so that the
heat that generated during operation can dissipate. Ensure that
the ventilation slots are not covered. Make sure that the device
is sufficiently far away from walls and other objects so that the
air can circulate.