ENGLISH 11
Type of gas used Type of
burner
Injector
marking
Rated
thermal
ow rate
kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure
(mbar)
BE FR min. rat. max.
NATURAL GAS
(Methane)
G20
power burner
semi-rapid
auxiliary
138 T2 A
101 Z
72 X
3,50
2,00
1,00
333 l/h
190 l/h
95 l/h
2,30
0,45
0,35
2,20
0,35
0,30
17 20 25
NATURAL GAS
(Methane)
G25
power burner
semi-rapid
auxiliary
138 T2 A
101 Z
72 X
3,50
2,00
1,00
388 l/h
221 l/h
111 l/h
2,20
0,35
0,30
20 25 30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
power burner
semi-rapid
auxiliary
93 T4 P
69
50
3,50
2,00
1,00
254 g/h
145 g/h
73 g/h
1,90
0,35
0,30
20
28
30
35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
power burner
semi-rapid
auxiliary
93 T4 P
69
50
3,50
2,00
1,00
250 g/h
143 g/h
71 g/h
1,90
0,35
0,30
25 37 45
Injector table
Category II2E+3+
Type of gas
used
Model
conguration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
)
for burning1m
3
of
gas
G20 20 mbar
1 PB - 2 SR
1 AUX
8,50 808 l/h 9,52
G25 25 mbar
1 PB - 2 SR
1 AUX
8,50 941 l/h 8,187
G30
28-30 mbar
1 PB - 2 SR
1 AUX
8,50 617 g/h 30,94
G31
37 mbar
1 PB - 2 SR
1 AUX
8,50 607 g/h 23,80
Electric Power: 220 - 240 V ~ 50/60 Hz