4 700/800 Series Food Waste Disposer
FAULT DIAGNOSIS
Machine does not start
Cause Action
Electrical supply is not turned on. Switch on supply.
The fuses have blown or the circuit
breaker has tripped.
Call site electrician to change fuse or
reset circuit breaker. If problem persists
contact service personnel.
Baffle is not correctly fitted. Check baffle is secured. If problem
persists contact service personnel.
Unexpected system stop
Cause Action
Electrical supply turned off. Switch on supply.
The fuses have blown or the circuit
breaker has tripped.
Call site electrician to change fuse or
reset circuit breaker. If problem persists
contact service personnel.
Baffle is not correctly fitted. Check baffle is secured. If problem
persists contact service personnel.
Waste jammed in disposer grinding
unit.
Remove blockage from grinding unit.
See instructions on page 3.
Motor overload has tripped. Allow motor to cool for 10 minutes and
restart. If problem persists contact
service personnel.
Waste not processed
Cause Action
A blockage has occured in the waste
pipe.
Clear blockage from waste pipe