J
John DavenportJul 29, 2025
What to do if the IMER Mixer motor doesn't run on position 1?
- SSelena LopezJul 29, 2025
If the motor of your IMER Mixer isn't running when switched to the '1' position, there could be several reasons: - There might be no power in the supply cable; check the cable. - The electric plug and socket might not be properly connected; ensure a proper connection. - The cable from the plug to the electric panel could be broken; replace the cable. - A wire might have become disconnected inside the panel or on the motor terminal board; remake the connection. - The switch could be faulty; replace the switch. - A fuse might have blown inside the panel; change the fuse. - The protection cover might be open; close it. - The limit switch might be faulty; replace it. - The cam might be incorrectly mounted; refer to limit switch adjustment "11.1".