Questions and Answers

  • B
    brookedeckerAug 11, 2025
    Why is the motor temperature of my iMettos B10 too high, and the speed is low?
    • J
      jacob94Aug 11, 2025
      If the motor temperature of your iMettos Mixer rises excessively and the speed is lower than expected, there could be several reasons. First, check the supply voltage, as a lack of voltage may be the cause. Second, reduce the load to prevent overload. Finally, ensure that you have selected a suitable speed and agitator for the task.
  • H
    hendersondanielleAug 19, 2025
    What to do if the raising handle on my iMettos B10 is too tight?
    • J
      janet43Aug 20, 2025
      If the raising handle of your iMettos Mixer is too tight, it could be due to corroded guide ways. To resolve this, clean and oil the guide ways. Alternatively, the lead screw, bevel gear, and hand wheel shaft might be dry; in this case, oil them.
  • J
    Joseph BirdAug 27, 2025
    How to fix iMettos Mixer when the mixing shaft doesn't rotate after switching on?
    • A
      Andrew RichardsAug 27, 2025
      If the mixing shaft of your iMettos Mixer does not rotate after switching it on, the electric connectors might be loose. Inspect the electric circuit and tighten any loose connectors.
  • T
    Tonya McdowellSep 3, 2025
    Why is my iMettos B10 Mixer leaking oil?
    • H
      Heather SmithSep 3, 2025
      If you notice oil leaking from your iMettos Mixer, it's likely that the oil seals are worn out. You will need to replace these oil seals to stop the leakage.

iMettos B10 Specifications

General IconGeneral
Voltage220-240V
Frequency50Hz
Speeds3
MaterialStainless steel
Power450 W
Bowl Capacity10 L