Page #21 background imageLoading...
Page #21 background image
IMPOSTA DATA E ORA
ANOMALY IN PROGRESS
Esc Reset
Alarm code
2-8
IMPOSTA DATA E ORA
Historical Alarm code
Esc Back
Historical index: 1
Alarm code: xxx
Alarm code
at 15:07 on 03 Jan 2014
2-9
21
INSTALLERUSER
MAINTENANCE TECHNICIAN
Menù Information
Menu item Description
Flow temperature Instant outlet temperature from the system
External temperature External temperature detected by the external probe
Flow temp. system calc. Flow temperature requested by the generators
Dew point Dew temperature
Firmware board version Heat pump board soware revision
Firmware display version Display soware revision installed on the remote panel
H.P. hours of operation Number of operating hours of the heat pump
Mode of operation H.P. Describes the heat pump operation mode.
Menù Historical alarm code
Description
Alarm reset
Historical alarm code, parag. 2.10
Menù Service
Menu item Description Range Default
Customised
value
Password protected menu dedicated to a qualied technician
Menù Language
Menu item Description Range Default
Customised
value
Language Denes the remote panel operation language ITA - ENG ITA
2.10 TROUBLESHOOTING.
e system signals any anomalies by displaying
the attention screen with the relative anomaly
code (Fig. 2-8).
Press the “esci” (exit) button to go back to the
main screen and the anomaly is displayed with
the symbol.
You must access the “Storico anomalie” (Anoma-
lies log) menu to display the anomalies log where
the last 10 system anomalies are displayed in time
order (Fig. 2-9). Turn the main switch to scroll
through the list.
From the “Anomalies log” menu, it is also possi-
ble to reset the list by selecting “Reset anomalie.

Other manuals for Immergas AUDAX TOP 6 ErP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas AUDAX TOP 6 ErP and is the answer not in the manual?

Immergas AUDAX TOP 6 ErP Specifications

General IconGeneral
BrandImmergas
ModelAUDAX TOP 6 ErP
CategoryHeat Pump
LanguageEnglish

Related product manuals