EasyManua.ls Logo

Immergas AUDAX TOP ErP Series User Manual

Immergas AUDAX TOP ErP Series
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HEAT PUMPS
with reversible inverter mono-
phase and three-phase air-
water Heat Pumps
AUDAX TOP ErP
AND INTEGRATED
SYSTEMS
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Immergas AUDAX TOP ErP Series and is the answer not in the manual?

Immergas AUDAX TOP ErP Series Specifications

General IconGeneral
BrandImmergas
ModelAUDAX TOP ErP Series
CategoryHeat Pump
LanguageEnglish

Summary

AUDAX TOP ErP Description

AUDAX TOP 6 - 8 - 12 ErP Features (Mono-phase)

System Solutions

Lists integration options for heat pump systems.

Available Models

List of available models and their product codes.

AUDAX TOP 16 - 18 - 21 ErP Features (Three-phase)

System Solutions

Lists integration options for heat pump systems.

Available Models

List of available models and their product codes.

Integrated System for Air Conditioning and D.H.W. Production

Control Panel: Settings and Logic Operation

Technical Features

Details of the control panel's standalone capabilities.

Programming Menu

Main Menu Items

Lists main menu items and their descriptions.

User Programming Menu

Menu Set Point Zone

Settings for zone temperature control.

Menu Set Point DHW

Settings for domestic hot water temperature.

Menu Time and Programs

Scheduling and time settings for system operation.

Menu Information

Displays system operating data and status.

Maintenance Technician Programming Menu

Menu Service Overview

Technician-level service and configuration menus.

Definition of Zone Settings

Settings for zone definition and control.

Device Configuration and Thermoregulation

Device Configuration

Settings for device configuration.

Thermoregulation - Heat

Settings for central heating thermoregulation.

Thermoregulation - Cool

Settings for cooling thermoregulation.

Integration and Heat Pump Parameters

Integration Settings

Settings for system integration.

Heat Pump Working Parameters

Parameters for heat pump operation.

Heat Pump System Modes and Manual Operation

Heat Pump System Modes

Indicates the system's operating mode.

Manual Operation Settings

Manual operation modes and settings.

Heat Pump Working Parameters

System Mode Indicator

Indicates the system's operating mode.

Heat Pump System State

Heat Pump System State and Auxiliary Information

Auxiliary Information

Provides auxiliary information about heat pump parameters.

Heat Pump PCB Settings and Test Procedures

PCB Settings

Settings related to the Printed Circuit Board.

Test Procedures

Procedures for testing system switches.

Manual Operation Modes

Manual operation modes and settings.

AUDAX TOP 6-8-12-16 ErP Dimensions and Connections

Condensate Drain and Base Connections

Details on condensate drainage and installation.

AUDAX TOP 18-21 ErP Dimensions and Connections

Condensate Drain Slots and Precautions

Information on condensate drainage slots and precautions.

AUDAX TOP 6-8-12-16 ErP Minimum Installation Distances

AUDAX TOP 18-21 ErP Minimum Installation Distances

Place of Installation Guidelines

Guidelines for proper installation location and placement.

AUDAX TOP 6-8 ErP Hydraulic Circuit Components

Hydraulic Diagram

Schematic of the hydraulic circuit for models.

AUDAX TOP 12-16 ErP Hydraulic Circuit Components

Hydraulic Diagram

Schematic of the hydraulic circuit for models.

AUDAX TOP 18-21 ErP Hydraulic Circuit Components

AUDAX TOP 6-8-12-16 ErP Operating Limits and Antifreeze Function

Central Heating Operating Limits

Operating limits and antifreeze function for central heating.

Cooling Operating Limits

Operating limits and antifreeze function for cooling.

AUDAX TOP 18-21 ErP Operating Limits and Antifreeze Function

Central Heating Operating Limits

Operating limits and antifreeze function for central heating.

Cooling Operating Limits

Operating limits and antifreeze function for cooling.

AUDAX TOP 6 ErP Technical Data

Central Heating Circuit Data

Technical specifications for the central heating operation.

Cooling Circuit Data

Technical specifications for the cooling operation.

General Data

General technical specifications and data.

AUDAX TOP 6 ErP Product Fiche

Low Temperature (30/35) Product Fiche

Product fiche data for low-temperature conditions.

Average Temperature (47/55) Product Fiche

Product fiche data for average-temperature conditions.

AUDAX TOP 6 ErP Power and COP - Central Heating

AUDAX TOP 6 ErP Power and EER - Cooling

AUDAX TOP 6 ErP Pump Flow Rate/Head Graph

Pump Settings and Configurations

Settings and configurations for the pump.

System Minimum Water Content Note

Note regarding system water content for defrost cycles.

AUDAX TOP 8 ErP Technical Data

Central Heating Circuit Data

Technical specifications for the central heating operation.

Cooling Circuit Data

Technical specifications for the cooling operation.

General Data

General technical specifications and data.

AUDAX TOP 8 ErP Product Fiche

Low Temperature (30/35) Product Fiche

Product fiche data for low-temperature conditions.

Average Temperature (47/55) Product Fiche

Product fiche data for average-temperature conditions.

AUDAX TOP 8 ErP Power and COP - Central Heating

AUDAX TOP 8 ErP Power and EER - Cooling

AUDAX TOP 8 ErP Pump Flow Rate/Head Graph

Pump Settings and Configurations

Settings and configurations for the pump.

System Minimum Water Content Note

Note on system water content for defrost cycles.

AUDAX TOP 12 ErP Technical Data

Central Heating Circuit Data

Technical data for central heating.

Cooling Circuit Data

Technical data for cooling.

General Data

General technical specifications.

AUDAX TOP 12 ErP Product Fiche

Low Temperature (30/35) Product Fiche

Product fiche data for low temperature.

Average Temperature (47/55) Product Fiche

Product fiche data for average temperature.

AUDAX TOP 12 ErP Power and COP - Central Heating

AUDAX TOP 12 ErP Power and EER - Cooling

AUDAX TOP 12 ErP Pump Flow Rate/Head Graph

Pump Settings and Configurations

Settings and configurations for the pump.

System Minimum Water Content Note

Note on system water content for defrost cycles.

AUDAX TOP 16 ErP Technical Data

Central Heating Circuit Data

Technical data for central heating.

Cooling Circuit Data

Technical data for cooling.

General Data

General technical specifications.

AUDAX TOP 16 ErP Product Fiche

Low Temperature (30/35) Product Fiche

Product fiche data for low temperature.

Average Temperature (47/55) Product Fiche

Product fiche data for average temperature.

AUDAX TOP 16 ErP Power and COP - Central Heating

AUDAX TOP 16 ErP Power and EER - Cooling

AUDAX TOP 16 ErP Pump Flow Rate/Head Graph

Pump Settings and Configurations

Settings and configurations for the pump.

System Minimum Water Content Note

Note on system water content for defrost cycles.

AUDAX TOP 18 ErP Technical Data

Central Heating Circuit Data

Technical data for central heating.

Cooling Circuit Data

Technical data for cooling.

General Data

General technical specifications.

AUDAX TOP 18 ErP Product Fiche

Low Temperature (30/35) Product Fiche

Product fiche data for low temperature.

Average Temperature (47/55) Product Fiche

Product fiche data for average temperature.

AUDAX TOP 18 ErP Power and COP - Central Heating

AUDAX TOP 18 ErP Power and EER - Cooling

AUDAX TOP 18 ErP Pump Flow Rate/Head Graph

Pump Settings and Configurations

Settings and configurations for the pump.

AUDAX TOP 21 ErP Technical Data

Central Heating Circuit Data

Technical data for central heating.

Cooling Circuit Data

Technical data for cooling.

General Data

General technical specifications.

AUDAX TOP 21 ErP Product Fiche

Low Temperature (30/35) Product Fiche

Product fiche data for low temperature.

Average Temperature (47/55) Product Fiche

Product fiche data for average temperature.

AUDAX TOP 21 ErP Power and COP - Central Heating

AUDAX TOP 21 ErP Power and EER - Cooling

AUDAX TOP 21 ErP Pump Flow Rate/Head Graph

Pump Settings and Configurations

Settings and configurations for the pump.

AUDAX TOP 6-8 ErP P.C.B.

AUDAX TOP 12 ErP P.C.B.

AUDAX TOP 16 ErP P.C.B.

AUDAX TOP 6-8-12-16 ErP Control Diagram

AUDAX TOP 6-8-12-16 ErP Terminal Block Electrical Connections

Terminal Block Pin Assignments

Pin assignments and signals for the terminal block.

AUDAX TOP 18-21 ErP P.C.B.

AUDAX TOP 18-21 ErP Control Diagram

AUDAX TOP 18-21 ErP Terminal Block Electrical Connections

Terminal Block Pin Assignments

Pin assignments and signals for the terminal block.

Electric Connection Cables Features

System Manager

Technical Features

Features and capabilities of the System Manager controller.

System Manager Electrical Connections

System Manager Technical Data

System Manager: Special Functions and Controls

Expansion Examples for Auxiliaries

Photovoltaic Contact Management

Configuration for photovoltaic contact management.

Domotic System Contact Management

Configuration for domotic system contact management.

Zone Remote Control

Room Temperature/Humidity Sensor

Expansion Board for Zone Management

System Distribution Kit

Dimensions and Connections

Physical dimensions and connection points for the kit.

Mixed Zone Kit Variants

Details of specific kit configurations.

Circulation Pump Technical Data

Circulation Pump Settings and Configurations

Settings and configurations for circulation pumps.

Circulation Pump Flow Rate/Head Graphs

Circulation Pump Flow Rate/Head Graphs (Continued)

Dehumidifier

Dimensions and Connections

Physical dimensions and connection details for the dehumidifier.

Dehumidifier Operating Principle

Dehumidification Mode with Neutral Air

Explanation of dehumidification with neutral air.

Dehumidifier Layout and Wiring Diagrams

Dehumidification Mode with Cooled Air

Explanation of dehumidification with cooled air.

Dehumidifier Technical Data

Hydraulic Circuit Load Loss

Data on hydraulic circuit load losses.

Integrated Systems: Main Applications

Diagram: AUDAX TOP ErP + System Kit + DHW Solar Heating

Diagram and explanation of a system configuration.

Diagram: AUDAX TOP ErP + Control Panel + DHW Solar Pack

Diagram and explanation of a system configuration.

Integrated System Diagrams with Boiler and Solar Heating

Hydraulic Diagram: AUDAX TOP ErP and 2 Low Temp Zones + Solar DHW + System Manager

Wiring Diagram: AUDAX TOP ErP and 2 Low Temp Zones + Solar DHW + System Manager

Hydraulic Diagram: AUDAX TOP ErP + Control Panel + Solar DHW

Wiring Diagram: AUDAX TOP ErP + Control Panel + Solar DHW

Hydraulic Diagram: AUDAX TOP ErP (AC) + Boiler PLUS + 2 Low Temp Zones + 1 Direct Zone + Solar DHW + System Manager

Wiring Diagram: AUDAX TOP ErP (AC) + Boiler PLUS + 2 Low Temp Zones + 1 Direct Zone + Solar DHW + System Manager

Hydraulic Diagram: AUDAX TOP ErP + Boiler + 1 High Temp Zone + 2 Low Temp Zones + Solar DHW + System Manager

Wiring Diagram: AUDAX TOP ErP + Boiler + 1 High Temp Zone + 2 Low Temp Zones + Solar DHW + System Manager

Hydraulic Diagram: AUDAX TOP ErP + Boiler PLUS + 2 Low Temp Zones + Storage Tank DHW + System Manager

Wiring Diagram: AUDAX TOP ErP + Boiler PLUS + 2 Low Temp Zones + Storage Tank DHW + System Manager

Hydraulic Diagram: AUDAX TOP ErP (AC) + Boiler + Storage Tank + Separate CH/Cooling + Solar DHW + System Manager

Wiring Diagram: AUDAX TOP ErP (AC) + Boiler + Storage Tank + Separate CH/Cooling + Solar DHW + System Manager

Hydraulic Diagram: AUDAX TOP ErP Cascade (AC) + High Output Boiler + Thermal Flywheel + Mixed Zone + Solar DHW + System Manager

Wiring Diagram: AUDAX TOP ErP Cascade (AC) + High Output Boiler + Thermal Flywheel + Mixed Zone + Solar DHW + System Manager

Hydraulic Diagram: AUDAX TOP ErP + Boiler + 2 Low Temp Zones + Solar DHW and CH + System Manager

Wiring Diagram: AUDAX TOP ErP + Boiler + 2 Low Temp Zones + Solar DHW and CH + System Manager

Optional Heat Adjustment

System Manager Heat Adjustment

Details on the System Manager for heat adjustment.

Zone Remote Control Heat Adjustment

Details on the zone remote control for heat adjustment.

Room Sensor and Chronothermostat Settings

Details on room sensors, humidistats, and chronothermostats.

Other Hydraulic and Installation Optionals

Zone and Auxiliary Expansion Kits

Expansion Kit for Zone/Auxiliary Management

Kit for zone or auxiliary management.

DHW/System Diverter Valve

3-way valve for DHW priority or system diverter.

Low Temperature Safety Kit

Safety kit for low temperature systems.

AUDAX TOP 18-21 ErP Optional Components

Storage Tank NTC Probe (Standalone)

NTC probe for storage tank (standalone applications).

Vibration-Dampening Feet Kit (Standalone)

Vibration-dampening feet kit (standalone applications).

Main Inertial Storage Tank Technical Features

Inertial Storage Tank Main Features

Key features of the inertial storage tanks.

25-Litre Horizontal Inertial Storage Tank

Technical data and diagram for a 25-litre storage tank.

75-Litre Horizontal Inertial Storage Tank

100-Litre Horizontal Inertial Storage Tank

200-Litre Horizontal Inertial Storage Tank

Declaration of Conformity

Product and Directive Declarations

Declarations of conformity for specific models and directives.

Related product manuals