EasyManuals Logo

Immergas AUDAX TOP ErP Series User Manual

Immergas AUDAX TOP ErP Series
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
AUDAX TOP ErP
29
10
15
20
25
30
35
40
45
50
55
60
65
70
-25 -20 -15 -10 -5 0 5 10 15 20 25 30 35
X2
Y2
X1
Y1
40
45
50
105
0
-5
15 20 25 30 35
0
2
4
6
8
10
12
14
16
18
20
AUDAX 18 TOP ErP
AUDAX 21 TOP ErP
10
15
20
25
30
35
40
45
50
55
60
65
70
-25 -20 -15 -10 -5 0 5 10 15 20 25 30 35
X2
Y2
X1
Y1
40
45
50
105
0
-5
15 20 25 30 35
0
2
4
6
8
10
12
14
16
18
20
AUDAX 18 TOP ErP
AUDAX 21 TOP ErP
9.1 AUDAX TOP 18  21 ErP OPERATING LIMITS AND ANTIFREEZE FUNCTION
Central heating
NOTE: AUDAX TOP 18-21 ErP is equipped with antifreeze
protection comprising an electrical resistance to protect the plate
exchanger which is the most critical component with regard to
freezing. When the electrical resistance activates so does the
pump inside the AUDAX TOP 18-21 ErP, in this way, with
power supply voltage, the machine is protected up to -10°C.
If AUDAX TOP 18-21 ErP is installed in areas having tempera-
tures below 0 °C, it is recommended to provide special antifreeze
systems in order to guarantee the machine's integrity, especially
the water-gas heat exchanger, when there is a blackout.
For example, insert top quality, non-hazardous antifreeze liquid
into the heating system.
Cooling
In this case, the instructions of the manufacturer of this liquid
must be followed scrupulously regarding the percentage necessary
with respect to the minimum temperature at which the system
must be kept.
An aqueous solution must be made with potential pollution class
of water 2 (EN 1717:2002).
With no supply voltage and if no antifreeze liquid has been
inserted, you must drain the water from the machine.
Avoid using automatic lling systems.
KEY:
Y2 - Flow water temperature (°C)
X2 - Outdoor air temperature (°C)
KEY:
Y1 - Flow water temperature (°C)
X1 - Outdoor air temperature (°C)
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas AUDAX TOP ErP Series and is the answer not in the manual?

Immergas AUDAX TOP ErP Series Specifications

General IconGeneral
BrandImmergas
ModelAUDAX TOP ErP Series
CategoryHeat Pump
LanguageEnglish

Related product manuals