AUDAX TOP ErP
11
5.3 USER PROGRAMMING MENU
Menu Set Point Zone
Menu item Description Range Default
Set comfort heat. Room temperature in central heating zone Comfort mode 15 ÷ 35 °C 20
Set economy heat. Room temperature in central heating zone Economy mode 5 ÷ 25 °C 17
Set ow heat. Flow temperature in room zone central heating mode 20 ÷ 60°C 40
Oset ow heat. Oset temperature for central heating zone
- 15 ÷ + 15
°C
0
Set comfort cool. Room temperature in cooling zone Comfort mode 15 ÷ 35 °C 25
Set economy cool. Room temperature in cooling zone Economy mode 15 ÷ 35 °C 28
Set ow cool. Flow temperature in room zone cooling mode 4 ÷ 25 °C 8
Oset ow cool. Oset temperature for cooling zone
-15 ÷ + 15
°C
0
Menu Set point DHW
Menu item Description Range Default
Set comfort DHW storage temperature in Comfort phase 30 ÷ 60 °C 50
Set economy DHW storage temperature in Economy phase 30 ÷ 45 °C 30
Menu Time and Programs
Menu item Description Range Default
Date and time Current date and time setting
Time slots Denes the time range for operation in Comfort and Economy mode
Program Zone Time programming for controlled zone
Mon - Fri
Cal 1
Sat - Sun
Cal 3
Program DHW DHW operation time programming
Mon - Sun
Cal 1
Program Holiday
Denes the period during which the system disables both hot water heating and
room central heating and/or cooling functions.
At the end of the set days, the previously active functions will be reset.
Disabled
Menu Information
Menu item Description
Flow temperature Instant outlet temperature from the system
Return temperature Instant inlet temperature to the system
External temperature External temperature detected by the external probe
Flow temp. system calc. Flow temperature requested by the generators
Dew point Dew temperature
Temp DHW Storage water temperature
Firmware board version Heat pump control board software revision
Firmware display version Display software revision installed on the control panel
H.P. hours of operation Number of operating hours of the heat pump
Mode of operation H.P. Describes the heat pump operation mode.
N.B. PARAMETERS ONLY VALID FOR AUDAX TOP 18 - 21 ErP
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas AUDAX TOP ErP Series and is the answer not in the manual?

Immergas AUDAX TOP ErP Series Specifications

General IconGeneral
BrandImmergas
ModelAUDAX TOP ErP Series
CategoryHeat Pump
LanguageEnglish

Related product manuals