AUDAX TOP ErP
20
Menu Service -> Test switch Max. press.
Menu item Description Range
Test pressure switch
Test method for high pressure switch.
N.B. to run the test, set the value to 1 and wait for the test result
0 = O
1 = Test required
N.B. the following states are managed by
the machine DO NOT USE
2 = AP Test in progress
3 = AP Test performed correctly
4 = AP Test failed for maximum time
reached
5 = AP Test failed for ow switch error
6 = AP Test failed for low water temper-
ature
7 = AP Test failed for inverter error
Menu Service -> Manual
Menu item Description Range Default
Manual operation
Forcing of the heat pump operation
N.B. all controls on the ow and return sensors are disabled with these
modes.
0 = O
1 = Test cooling
2 = Test central heating
3 = Test cooling with
ramp
4 = Test central heating
with ramp
0
Circulator speed Pump speed forcing 0% ÷100% 0%
Flow switch Indicates circulation inside the hydraulic circulator O/On
ree way DHW Force the output for the DHW 3-way control O/On O
N.B. PARAMETERS ONLY VALID FOR AUDAX TOP 18 - 21 ErP
Menu Heat Pump -> P.C.B. settings
Menu item Description Range
Unit Type It establishes whether the machine is of reversible type
- Central heating
- Cooling
- Central heating + Cooling
Unit Size It establishes the Unit power
- 6 KW
- N.A.
- 8 KW
- N.A.
- N.A.
- N.A.
- 12 KW
- N.A.
- N.A.
- N.A.
- 16 KW
- N.A.
- 18 KW
- N.A.
- N.A.
- 21 KW
Power Supply
integration
It denes the Unit power supply voltage 230Vac - 400Vac
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua