Average temperature table (47/55) colder zones
Model: Audax TOP 6 ErP
Air/water heat pump: yes
Water/water heat pump: no
Brine/water heat pump: no
Low temperature heat pump: no
With additional central heating device: no
Mixed central heating device with heat pump: no
e parameters are declared for average temperature application, except for low temperature heat pumps. e parameters for low temperature heat
pumps are declared for low temperature application
e parameters are declared for colder climatic conditions
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output
Nominal
output
6.65 kW
Room central heating season-
al energy eciency
η
s
112 %
Central heating capacity declared with a partial load and indoor
temperature equivalent to 20°C and outdoor temperature Tj
Performance coecient declared with indoor temperature equivalent
to 20°C and outdoor temperature TJ
T
j
= –7°C Pdh 4.0 kW T
j
= –7°C COPd 2.14 -
T
j
= +2°C Pdh 2.4 kW T
j
= +2°C COPd 3.41 -
T
j
= +7°C Pdh 1.6 kW T
j
= +7°C COPd 4.71 -
T
j
= 12°C Pdh 0.8 kW T
j
= 12°C COPd 7.50 -
T
j
= bivalent temperature Pdh 4.0 kW T
j
= bivalent temperature COPd 2.14 -
T
j
= temperature operating
limit
Pdh 3.8 kW
T
j
= temperature operating
limit
COPd 1.94 -
for air/water heat pumps: Tj
= –15°C
(if TOL < –20°C)
Pdh kW
for air/water heat pumps: Tj
= –15°C
(if TOL < –20°C)
COPd -
Bivalent temperature T
biv
-7 °C
for air/water heat pumps: tem-
perature operating limit
TOL -20 °C
Central heating capacity cycle
intervals
Pcych kW Cycle intervals eciency
COPcyc or
PERcyc
-
Degradation coecient Cdh 0.9 -
Water heating temperature
operating limit
WTOL 60 °C
Dierent mode of energy consumption from the active mode Additional heating appliance
OFF mode P
OFF
0.000 kW Nominal heat output Psup 2.48 kW
ermostat mode o P
TO
0.037 kW
Type of energy supply voltage electricalStandby mode P
SB
0.050 kW
Guard heating mode P
CK
0.050 kW
Other items
Capacity control Variable
For air/water heat pumps:
nominal air output to outside
- 2600 m
3
/h
Indoor/outdoor sound level L
WA
x / 62 dB
For water or brine/water heat
pumps: nominal ow of brine or
water, outdoor heat exchanger
- m
3
/h
Annual energy consumption Q
HE
5431
kWh or
GJ
For mixed central heating appliances with a heat pump
Stated load prole
Water central heating energy
eciency
η
wh
%
Daily electrical power con-
sumption
Q
elec
kWh Daily fuel consumption Q
fuel
kWh
annual energy consumption AEC kWh Annual fuel consumption AFC GJ