AUDAX TOP 8 ErP
55 °C 35 °C
dB
A
++
A
+
A
B
C
D
E
F
G
kW kW
dB
A
+
A
6.46
5.09
6.59
4.65 4.56
4.83
64
44
Low temperature (30/35)
Parameter Value
Colder zones
Average
zones
Hotter zones
Annual energy con-
sumption for the heating
function (Q
HE
)
kWh/year 5381 3088 1624
Room central heating
seasonal eciency (η
s
)
ηs % 110 118 163
Nominal heat output kW 6.46 4.56 5.09
Average temperature (47/55)
Parameter Value
Colder zones
Average
zones
Hotter zones
Annual energy con-
sumption for the heating
function (Q
HE
)
kWh/year 5867 3367 1649
Room central heating
seasonal eciency (η
s
)
ηs % 103 111 152
Nominal heat output kW 6.59 4.65 4.83
For proper installation of the appliance refer to chapter 1 of this booklet (for the installer)
and current installation regulations. For proper maintenance refer to chapter 3 of this booklet
(for the maintenance technician) and adhere to the frequencies and methods set out herein.