Imovilli Pompe S.r.l.
Reggio Emilia – Italy
www.imovillipompe.it
Manuale d’officina – Pompe a membrana 1/11
WORKSHOP MANUAL
DIAPHRAGM PUMPS
1.0
A-M VALVE ZONE CONTROL on pumps with internal manifolds
(M25 – M29 – M30 – M35 – M 50 – M60 – M73 – M104S – M135S)
1.1 Remove the valve covers and remove the A-M valves
from the cylinder head
NOTE: The suffix A-M means "Suction / Delivery"; in
fact, the pump valves can be used indifferently in
suction and delivery
1.2 Break down the valves into the individual elements and
proceed with their inspection; if a component is
particularly worn or damaged they will need to be
replaced.
1.3 Check the inside of the valve covers: if they show signs
of wear in the contact areas with the valve caps or
damage in the plasticization, they must be replaced.
Question and Answer IconNeed help?

Do you have a question about the IMOVILLI M25 and is the answer not in the manual?

Summary

1.0 A-M Valve Zone Control (Internal Manifolds)

Remove Valve Covers and A-M Valves

Remove the valve covers and the A-M valves from the cylinder head.

Valve Disassembly and Inspection

Break down valves into individual elements for inspection.

2.0 Tested Control in the A-M Valve Zone

3.0 Reassembly

4.0 A-M Valve Zone Control (External Manifolds)

5.0 Reassembly

6.0 Diaphragm Control and Replacement

Diaphragm Removal and Condition Checks

Remove diaphragms and inspect for swelling, cuts, or piston contact.

7.0 Cylinder Control

Shaft and Bearing Service

Reassembly and Initial Startup

Air Bleeding Procedure

Bleed air from the pump after reassembly and oil filling.

Post-Maintenance Startup and Air Bleeding

Initial Startup and Progressive Operation

Start with pressure canceled, gradually increase speed/pressure, cycle pump.

Final Checks and Stable Operation

Repeat procedures, monitor pressure/vibrations for stable pump noise.

IMOVILLI M25 Specifications

General IconGeneral
Pressure1.5 bar
Power0.37 kW
Max Head15 m
Voltage220-240V
Frequency50 Hz
Inlet/Outlet Size1 inch
Flow25 m³/h
Max Flow Rate25 m³/h