Remove valve covers and A-M valves from the cylinder head.
Disassemble valves for inspection; replace worn components.
Inspect valve covers for wear or damage in contact areas and replace if needed.
Inspect diaphragms for swelling, cuts, erosions, scratches, or leaks indicating failure.
If a diaphragm breaks, disassemble the crank mechanism for inspection.
Bleed air from the pump by tilting and rotating the shaft until no bubbles appear.
Follow procedures for initial pump start-up after maintenance to purge air and ensure functionality.
| Flow rate | 30 L/min |
|---|---|
| Inlet | 1 inch |
| Outlet | 1 inch |
| Inlet/Outlet Size | 1 inch |
| Voltage | 230 V |
| Frequency | 50 Hz |
| Material | Cast Iron |
| Power | 750 W |
| Max Flow Rate | 40 L/min |