HVAC Testing
When testing the HVAC (Climate Function), make sure each “Zone” is
displaying a room (Zone) temperature. Use the “Mode” button to
cycle through Fan, Cool, Heat and Auto modes. (Heat and Auto
modes availability depend on the floor plan.)
Use the “Set” temperature up and down arrows to set the desired
temperature. The “Set” temperature can be adjusted between 55 to 90F.