21
Page 21 - 6 Tank Sentinel Setup Programming Guide
DATA MODE Menu (Continued... )
AUTODIAL Press M2 key.
DATA AUTODIAL
NUMBER 1 (Automatically dials up to 4 numbers
NUMBER 2 when Deliveries, Alarms or Leaks occur.)
NUMBER 3 Program numbers below:
NUMBER 4
(N = number 1, 2, 3, or 4)
DATA NUMBERS N
ACCESS CD (Use the Access Code field when
ACCESS CODE N phone number is longer than 12
characters - see example)
blank
12 characters
Use keypad to input access code.
Press
ENTER
to accept this data.
PHONE NUM (Input the phone number to autodial)
PHONE NUMBER N
blank
12 characters
(if more than 12 characters - see example)
Use keypad to input phone number.
Press
ENTER
to accept this data.
REDIAL EN (ENABLED allows re-dialing of the phone number)
REDIAL ENABLE N
DISABLED
Use
UP/DOWN
to show choices.
ENABLED Press
ENTER
to accept this data.
— Press the
CANCEL
key to return to the DATA AUTODIAL Menu —
— Press the
DOWN
key to show more menu items —
— continued on the next page —
ACCESS CODE or PHONE No. AT Command Characters:
D = (
,
) comma = Dial Delay
Example —
88DD88DD912072830156
(20 character phone number)
‘Switching code’=
88
Dial Delays=
DD
“to dial out”=
9
“long distance”=
1
Access Code:
88DD88DD91
(10) Phone Number:
2072830156
(10)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Incon task sentinel TS-504 and is the answer not in the manual?

Incon task sentinel TS-504 Specifications

General IconGeneral
BrandIncon
Modeltask sentinel TS-504
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals