EasyManua.ls Logo

Indesit ICD661UK - Test Cycle

Indesit ICD661UK
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15 of 28
Indesit Company
Service Manual UK English
TEST CYCLE
To start the Test Cycle:-
1. Switch the machine off at (On-Off button). The machine must be 'OFF' to start the Test Cycle.
2. Close the door and press the Power and Start/Pause buttons together until all LEDs flash
quickly.
3. Press the Start/Pause button, to start the Test Cycle.
Note: - During the Test Cycle the programme progress lamps will flash on and off in
sequence.
STEP STATE
Initialize Power On, Stand-By
Inlet Valve Inlet valve On and takes in water 1.9 litres (controlled by Flowmeter);
Dispenser/
Wash Pump
Dispenser opens and wash pump runs (60 seconds);
Heating Element/
Wash Pump
Wash pump runs and heating element on, up to 60°C (by thermistor);
NOTE: - To forward to the next step by press the Start/Pause button.
Drain Pump Drain pump (60 seconds);
Pause (15 seconds)
Inlet Valve Inlet Valve on, 1.9 litres (by Flowmeter);
Wash Pump Wash pump on (180 seconds);
Pause (5 seconds);
Wash Pump Wash pump on (180 seconds);
Drain Pump/
Softener Valve
Softener valve on and the drain pump (60 seconds);
Finish 1 Buzz test finishes, then power on again to Stand-By.