15 of 28
Indesit Company
Service Manual UK English
TEST CYCLE
To start the Test Cycle:-
1. Switch the machine off at (On-Off button). The machine must be 'OFF' to start the Test Cycle.
2. Close the door and press the Power and Start/Pause buttons together until all LEDs flash
quickly.
3. Press the Start/Pause button, to start the Test Cycle.
Note: - During the Test Cycle the programme progress lamps will flash on and off in
sequence.
STEP STATE
Initialize Power On, Stand-By
Inlet Valve Inlet valve On and takes in water 1.9 litres (controlled by Flowmeter);
Dispenser/
Wash Pump
Dispenser opens and wash pump runs (60 seconds);
Heating Element/
Wash Pump
Wash pump runs and heating element on, up to 60°C (by thermistor);
NOTE: - To forward to the next step by press the Start/Pause button.
Drain Pump Drain pump (60 seconds);
Pause (15 seconds)
Inlet Valve Inlet Valve on, 1.9 litres (by Flowmeter);
Wash Pump Wash pump on (180 seconds);
Pause (5 seconds);
Wash Pump Wash pump on (180 seconds);
Drain Pump/
Softener Valve
Softener valve on and the drain pump (60 seconds);
Finish 1 Buzz test finishes, then power on again to Stand-By.