SCM2 test procedure
MODEL
TEST PROCEDURE
ICON AND ASSOCIATED LOAD
ACTIVATION
LOAD TEST
MODE
Scholtès Touch Super Vapour
With the machine on stand-by
(off but with the main on/off
switch set to I), open the service
door and press and hold the 1
CUP, STRENGTH and MENU
keys at the same time for at least
6 seconds, or until the message
“SELECT TEST” appears on the
display. After this, shut the
service door and press the
STEAM icon: LOAD TEST MODE
will appear on the display.
To exit test mode, unplug from
the power supply.
ICON
LOAD
Long/short
PUMP
Key Lock
MOTOR UP +
LIGHT
Menu HEATER
Strength STEAM UNIT
2 cups
1 cup
Steam
Solenoid 1 +
Solenoid 2
UP menu GRINDER
Hot water
MOTOR DOWN
Solenoid valve 2
(brew head) + FAN
Solenoid valve 1
(drain)