CONTROL PANEL CONNECTION
*
*
NTS
B
CP CON REGEN 10/31/07
11
D.WRIGHT
SW1
GROUND
LT1
ENCL.
COMP.
TO
120 VAC
SOURCE
PS
FUSE
COMP.
TO
G
H
N
G
TO COMP.
AIR LINE
FS1
BUZZER
*TIME DELAY
F2
F1
H
N
N
TB
Air Filter
Check Valve
SECTION A-A
A
A
SETTING HIGH LEVEL PRESSURE SWITCH
– BRING PLANT TO OPERATING LEVEL
WITH COMPRESSOR TURNED ON
– USING PROPERLY SIZED SCREWDRIVER,
TURN HIGH LEVEL ALARM ADJUSTMENT
– SCREW CLOCKWISE UNTIL ALARM OCCURS,
THEN TURN THE SCREW COUNTERCLOCKWISE
UNTIL ALARM STOPS.
1/4" AIR LINE TO
CONTROL PANEL
PRESSURE
SWITCH
TUBING
BLOWER
ENCLOSURE
AIR PIPING
TO TREATMENT
PLANT
2" SCH. 40
PVC PIPE
FRONT VIEW
DOOR OPEN
CP22
HIGH LEVEL ALARM
ADJUSTMENT SCREW
REVISION DESCRIPTIONREV.DATE
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL,
SOLELY FOR THE PURPOSE PROVIDED, AND IT IS NOT TO BE DISCLOSED TO
COMPANY CONFIDENTIAL:
IT IS THE PROPERTY OF DELTA TREATMENT SYSTEMS, IT IS TO BE USED
OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF
DELTA TREATMENT SYSTEMS
.
BY
PLOT SCALE
SHEET
OF
DRAWN BY
DATE
REVDRAWING NUMBER
CONTROL PANEL CONNECTION