25
Checks, Adjustments and Maintenance Procedures To Be
Carried Out After The First 50 Running Hours
NOTE:
This the first compulsory maintenance call (other than daily and monthly inspections) to
be carried out by your Ingersoll-Rand dealer.
Before performing any operation on the generating set, ensure that cannot be
started. To avoid an unwanted start, disconnect the battery cables.
Engine
Cold Engine
Check and adjust the valve clearance.
Check the water level and top off if necessary.
Check the tightness of bolts and screws and particularly the air and exhaust manifolds and
engine support.
Replace the fuel filter cartridge.
Warm Engine
Start the engine, bring it to its normal running temperature, and then stop it.
Drain the oil.
Replace the oil filter cartridge and fill up with new, clean and approved oil to the top mark of the
dipstick.
Restart the engine and ensure that there is no oil, fuel, exhaust gas or combustion air leaks.
Stop the engine and after a few minutes check the oil level.
Top off the oil level if necessary.

Table of Contents

Other manuals for Ingersoll-Rand 4IRQ2N

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ingersoll-Rand 4IRQ2N and is the answer not in the manual?

Ingersoll-Rand 4IRQ2N Specifications

General IconGeneral
BrandIngersoll-Rand
Model4IRQ2N
CategoryEngine
LanguageEnglish

Related product manuals