© 2012 Ingersoll Rand All Rights Reserved
Upflow/ Horizontal, Downflow/ Horizontal, Gas-Fired, Direct Vent
Condensing Furnaces
INSTALLER'S GUIDE
M95 Upflow models can also be used in the
Horizontal Left configuration.
M95 Downflow models can also be used in the
Horizontal Right configuration.
A341624P16
M95 Furnace
18-CD35D1-4
OPTIONAL ACCESSORIES
Model Number Description
BAYBASE205 Downflow subbase for downflow models only
BAYFLTR200 External side filter rack
BAYFLTR203 Filter kit horizontal for 17.5" cabinet
BAYFLTR204 Filter kit horizontal for 21" cabinet
BAYFLTR205 Filter kit horizontal for 24.5" cabinet
BAYFLTR317 Cleanable filter for 17.5" cabinet upflow only
BAYFLTR321 Cleanable filter for 21" cabinet upflow only
BAYFLTR324 Cleanable filter for 24.5" cabinet upflow only
BAYLPKT210B Propane conversion kit
BAYLPSS210B LP kit with stainless steel burners
BAYMFGH100A Manufactured / mobile home kit
BAYRACK960A Internals filter rack kit for upflow models
BAYAIR30AVENTA Concentric vent kit for 2,2.5,3" vent system
BAYVENT200B Sidewall vent termination kit for direct vent furnaces
BAYVENT500A Side vent kit for downflow models only
BAYSWT01AHALTA High altitude switch kit - UF/DF 040, DF 085
BAYSWT04AHALTA High altitude switch kit - UF 060, 100, UF 120
BAYSWT05AHALTA High altitude switch kit - UF 080, 100, DF 110
BAYSWT12AHALTA High altitude switch kit - DF 065
KIT09224 Filter clip kit
BAYBRCKFLT10 Downflow bracket kit
ALL phases of this installation must comply with
NATIONAL, STATE AND LOCAL CODES
IMPORTANT This Document is customer property and is to
remain with this unit. Please return to service
information pack upon completion of work.
M951P040BU24AA
M951P060BU36AA
M951P080BU42AB
M951P100CU48AA
M951P100DU60AA
M951P120DU60AA
M951P040BD24AA
M951P065BD42AA
M951P085CD48AA
M951P110DD60AA
Question and Answer IconNeed help?

Do you have a question about the Ingersoll-Rand M951P040BU24AA and is the answer not in the manual?

Ingersoll-Rand M951P040BU24AA Specifications

General IconGeneral
BrandIngersoll-Rand
ModelM951P040BU24AA
CategoryFurnace
LanguageEnglish

Summary

INSTALLATION INSTRUCTIONS

SAFETY SECTION

Essential safety practices and precautions for installation, servicing, and operation.

CARBON MONOXIDE POISONING HAZARD

Warning about CO poisoning risks and required steps for safe venting system operation.

GENERAL INSTALLATION INSTRUCTIONS

FIRE OR EXPLOSION HAZARD

Warning regarding potential hazards from failure to follow safety warnings.

LOCATION AND CLEARANCES

OUTSIDE AIR IS RECOMMENDED

AIR FOR COMBUSTION AND VENTILATION

Ensuring adequate airflow for combustion and ventilation per codes.

DUCT CONNECTIONS

GENERAL VENTING

VENTING MATERIAL

HORIZONTAL VENTING

VENT CLEARANCES

IMPORTANT: (MASSACHUSETTS REGULATIONS)

INSTALLATION OF CARBON MONOXIDE DETECTORS

Requirements for installing CO detectors in dwellings with side wall vented appliances.

APPROVED CARBON MONOXIDE DETECTORS

Standards and certifications for approved carbon monoxide detectors.

HORIZONTAL INSTALLATION

CONDENSATE DRAIN INSTRUCTIONS VERTICAL APPLICATIONS

Recommended installation of drain pans and tubing for vertical condensate drainage.

ELECTRICAL CONNECTIONS

GAS PIPING

COMBUSTION AND INPUT CHECK

HIGH ALTITUDE DERATE

START UP AND ADJUSTMENT

LIGHTING INSTRUCTIONS

Step-by-step guide for safely lighting the furnace burners.

SEQUENCE OF OPERATION

ABNORMAL CONDITIONS

IFC ERROR FLASH CODE