SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and
air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered
equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the
literature and on the tags, stickers, and labels that are attached to the equipment.
January 2016
18-GF74D1-1F-EN
Convertible Air Handlers
2 5 Ton
TEM6A0B24H21S
TEM6A0B30H21S
TEM6A0C36H31S
TEM6A0C42H41S
TEM6A0C48H41S
TEM6A0D48H41S
TEM6A0C60H51S
TEM6A0D60H51S
The TEM6 series air handler is designed for installation in a closet,
utility room, alcove, basement, crawlspace or attic. These versatile
units are applicable to air conditioning and heat pump
applications. Several models are available to meet the specific
requirements of the outdoor equipment. Field installed electric
resistance heaters are available.
Installers Guide
Question and Answer IconNeed help?

Do you have a question about the Ingersoll-Rand TEM6A0B24H21S and is the answer not in the manual?

Ingersoll-Rand TEM6A0B24H21S Specifications

General IconGeneral
BrandIngersoll-Rand
ModelTEM6A0B24H21S
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Section Air Handlers

Hazardous Voltage Warning

Warns of severe injury/death from hazardous voltage; requires power disconnect.

Grounding Required Caution

Emphasizes grounding importance for preventing damage and injury.

Live Electrical Components Warning

Warns about live components; requires precautions during service.

Pressurized Refrigerant Warning

Warns of personal injury from pressurized refrigerant; requires recovery.

Sharp Edge Hazard Caution

Alerts to sharp edges, requiring care during installation/servicing.

Hazardous Vapors Caution

Warns of corrosive vapors from construction materials affecting the unit.

Coil Pressurized Caution

Informs about coil pressurization with dry air and leak checks.

Fiberglass and Ceramic Fiber Hazard

Warns of fiberglass/ceramic fiber inhalation risks causing cancer.

Appliance Use Restrictions

Restricts use by persons with reduced capabilities without supervision.

Child Supervision Advisory

Advises supervision of children to prevent them from playing with the appliance.

Installation Instructions

Unpacking and Inspection

Instructions for unpacking, inspecting for damage, and reporting discrepancies.

Unit Location Requirements

Guidance on selecting a central, accessible location with proper clearances and drainage.

Ductwork Installation Standards

Requirements for installing ductwork according to standards and codes.

Condensate Drain Setup

Details on installing and piping condensate drains for proper drainage.

Field Wiring

Single Stage Cooling Wiring Diagram

Wiring diagram for single-stage cooling-only thermostat connections.

Single Stage Heat Pump Wiring Diagram

Wiring diagram for single-stage heat pump thermostat connections.

Two Stage Cooling Wiring Diagram

Wiring diagram for two-stage cooling-only thermostat connections.

Two Stage Heat Pump Wiring Diagram

Wiring diagram for two-stage heat pump thermostat connections.

Subcooling Adjustment

Subcooling Adjustment for Specific Models

Specifies sub-cooling charge for specific AHRI rated performance models.

Coil Conversion Instructions

Downflow Configuration Conversion

Steps to convert the air handler for downflow installation configuration.

Horizontal Right Configuration Conversion

Steps to convert the air handler for horizontal right installation configuration.