Specifications

Communication
Vehicle communication Charging current controlled via PWM pilot signal in accordance with IEC 61851-1:2017
Direct communication Bluetooth Class 1 and 2 (power level)
Backend connection Via OCPP 1.6J to innogy backend or third-party backends
Backend communication
WLAN with 2.4 GHz IEEE 802.11 b/g/n with WPA2
(antenna gain, frequency-dependent, max. 4.6 dBi)
or LAN
or mobile radio via SIM card (frequency and direction dependent, maximum 4.4 dBi antenna gain);
With use of private innogy software services only via WLAN or LAN
Authentication
Authentication
Free charging, smartphone app (innogy eCharge+ app/third-party apps) via contract charging
or direct payment via epowerdirect.com
Plug & charge (ISO 15118) Ye s
RFID authentication
Yes, according to ISO 14443A, Type V (ISO/IEC 15693/Vicinity). Supported protocols:
MIFARE Classic 1K, MIFARE Classic 4K, MIFARE DESfire V1 4K, MIFARE DESfire V2 4K,
MIFARE DESfire V1 8K, MIFARE DESfire V2 8K, MIFARE Ultralight Standard,
MIFARE Ultralight C, MIFARE Ultralight NXP NTAG 216, MIFARE Plus SE 1K,
MIFARE Plus X 2K, LEGIC advant ATC 1024-MV, Legic advant ATC 4096,
J3A081 JCOP 2.4.1 Rev 3, ICODE SLIX, ICODE ISO, TAG-IT HFI plus 2048 and SLE 66 R 35