TROUBLESHOOTING
If you are experiencing an operating problem, it is recommended to contact your spa dealer or a qualied service technician to arrange servicing. Some
problems can be disgnosed and rectied with a simple action or procedure. Below are some common problems, possible causes and simple actions that
may help to solve them.
THE CIRCUIT BREAKER IMMEDIATELY TRIPS WHEN THE SPA IS STARTED
1. If your spa is wired for a 220V electrical supply with a 50A GFCI breaker, ensure that the wiring from the house panel to the breaker
and from the breaker to the spa is done correctly. Occasionnally, the white common wire is improperly connected and the breaker
trips immediately.
2. If you are using the 110V GFCI cord supplied with the spa, ensure that the circuit that you have plugged it into is dedicated to the
spa only and that no other appliances are using the same circuit. This could cause an amp overload and trip the breaker. NEVER
USE AN EXTENSION CORD.
3. The problem could be a defective breaker, component or heater element. It is recommended that a qualied technician perform this
troubleshooting.
NOTHING OPERATES WHEN YOU CONNECT ELECTRICITY TO THE SPA
1. Check the breaker to ensure it hasn’t tripped. If it is tripped, reset it and try again.
2. Using a voltmeter, check to ensure that there is power to the spa pack. This is done by removing the cover of the equipment pack.
It is recommended that a qualied technician perform this troubleshooting.
THE PUMP LIGHT GOES ON, BUT THERE IS NO WATER FLOW TO THE JETS
1. Ensure that any gate valves located in the equipment enclosure are in the open position.
2. Ensure that the jets are in their open position.
3. Ensure that your lter is not dirty and causing a ow restriction.
4. The pump may not be properly primed. Push the «Jets» button several times. It may take several minutes for the pump to prime.
THE PUMP RUNS CONTINUOUSLY OR WILL NOT SHUT OFF WHEN THE «JETS» BUTTON IS DEPRESSED
1. The pump runs as long as there is a heat demand. Ensure that the air control valves are in their closed position when you are not
using the spa. If they are open, they will allow cold, ambiant air to enter your spa water, especially in cold weather, and the pump
will continue to run to keep up with the heat demand.
2. Ensure that your lter cycle setting is not set on continuous.
3. Even if you press the «Jets» button to turn it off, the pump will continue to operate on low speed if your spa requires heat or is in a
lter cycle.
SPA WATER TEMPERATURE EXCEEDS SET TEMPERATURE AND WATER IS VERY HOT
1. DO NOT ENTER THE SPA. Remove the cover and allow the spa water to cool down.
2. In hot climates, spa water can overheat from high ambient air temperatures, direct sunlight on your spa or from heat transfer from
the pump during lter cycles. Readjust your safety straps and place a small object between the cover and the spa to slightly wedge
it open. This will help to keep the water cooler.
WATER LEVEL IN THE SPA IS DROPPING FASTER THAN NORMAL
1. If your spa has been used more than normal, it could be a result of more splashing and added evaporation.
2. Remove the access door to the equipment and inspect for water on the oor of the spa cavity. If there is water, check and ensure
that your unions are properly tightened. Check your jets housings and plumbing to try to identify a plumbing leak.
It is recommended to contact your manufacturer a qualied service technician for spa service.