    What to do if Inovance IS650PT032IUX-B Servo Drives LED display is not on?
    • A
      Allen RamirezAug 3, 2025
      If the Inovance Servo Drives LED display is not on, there could be several reasons: 1. The control power voltage may be abnormal. Disconnect CN1, CN2, CN3, and CN4, and then measure the AC voltage between L1C and L2C. 2. The main power voltage may be abnormal. For single-phase 220 V models, measure the AC voltage between L1 and L2. If the DC bus voltage amplitude (voltage between P and -) is lower than 200 V, "nrd" will be displayed. For three-phase 220/380 V models, measure the AC voltage between R, S, and T. If the DC bus voltage amplitude (voltage between P and -) is lower than 460 V, "nrd" will be displayed. 3. The program burning terminal may be shorted. Check the program burning terminal to ensure it is not shorted.

Summary

Safety Information and Precautions

Electrical Safety and Hazards

Precautions against electrical shock, burns, and hazards during operation and installation.

Personnel and System Safety

Guidelines for trained personnel, system design, installation, and electrical safety.

Chapter 5 Troubleshooting

5.1 During Startup

Troubleshooting common issues encountered during the initial startup phase.

5.2 During Running

Troubleshooting common problems that occur during normal operation.

Chapter 6 Parameter Table

Tuning, Faults, and Protection

Parameters for gain tuning, fault handling, and protection settings.

Inovance IS650PT032IUX-B Specifications

General IconGeneral
Rated Input Voltage3-phase 380-480 VAC
Rated Output Current32 A
CommunicationCANopen, EtherCAT
Input Voltage3-phase 380-480 VAC
Output Current32 A
Power15 kW
Control ModePosition, Speed, Torque
Communication InterfaceCANopen, EtherCAT
Humidity5% to 95% (non-condensing)
Protection FeaturesOvervoltage, Overcurrent
Operating Temperature0 to 40 °C
Storage Temperature-20 to 60 °C