EasyManuals Logo

Inovance MDBUN-60-5T User Manual

Inovance MDBUN-60-5T
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Inovance MDBUN Series Braking Unit User Manual
Page 17 of 24
P2-01
Types of
latest four
faults
-
This parameter
specifies the latest
four fault types.
The digit in the unit's
place is the type of
the latest fault, and
the digit in the ten's
place is the type of
the latest second
fault, by analogy.
-
-
P2-02
Bus
voltage
upon fault
-
This parameter
specifies the bus
voltage when the
latest fault occurs.
-
-
P2-03
Current
upon fault
-
This parameter
specifies the current
when the latest fault
occurs.
-
-
P2-04
Braking
rate upon
fault
-
This parameter
specifies the braking
rate (duty ratio) when
the latest fault occurs.
-
-
P2-05
Module
temperatu
re upon
fault
-
This parameter
specifies the module
temperature when the
latest fault occurs.
-
-
P2-06
Braking
unit status
upon fault
-
This parameter
specifies the status of
the braking unit when
the latest fault occurs.
bit0: DI
bit1: DO
bit2: fan
bit3: relay
bit4: braking
bit5: power-on
detection
bit6: current sampling
detection
bit7: bus voltage
setup
-
-
P2-07
Running
time
before
fault
-
This parameter
specifies the running
time (in unit of
seconds) when the
latest fault occurs.
The time is measured
starting from this
power-on, and is
cleared in the case of
power-on again or
fault.
-
-
P2-08
Accumulat
ive
braking
time
-
This parameter
specifies the
accumulative braking
time, in unit of
-
-