FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY
- 5 -
ADDITIONAL NOTES:
Temperature
NOTE
Fahrenheit/Centigrade (Celsius)
Conversion
The temperature controller can be
programmed to display either °F or °C.
To change:
Press the MODE button until the
temperature is displayed, then push and
hold the SET button for 10 seconds.
Timer
• The controller has a count down timer that
automatically activates a buzzer at the
completion of the application.
• Timer display is minutes:seconds. Range is
00:00 to 10:00, Colons (:) flash while timer is
running.
NOTE
The timer or buzzer may be stopped
while the handle is in the down
position by pressing both the DOWN
(
↓
) arrow button and the UP (
↑
) arrow
button simultaneously. The timer will
automatically reset after the handle is
raised.
Counter
The controller has a built in cycle counter.
• Press MODE button until the counter is
displayed.
• Counter display range is 0000 to 9999.
• To reset the cycle counter, display the counter
reading, then push and hold both UP (↑) and
DOWN (↓) arrow buttons for 3 seconds until
the counter resets to zero (0000) on the
display.