Quick Start Guide MEDIACLAVE 10/30 Media Sterilizer
This quick start guide is intended to provide a quick overview of your MEDIACLAVE’s
(MC) key features and to offer basic instructions for getting started. For
detailed
information, please refer to the operating instructions (OI)
that can be found at
www.integra-biosciences.com in different languages.
Intended use
This is a general-purpose laboratory instrument. Any use of this instrument in a medical or IVD setting
is the sole responsibility of the user. MEDIACLAVE 10/30 is used for the preparation and sterilization
of media and can easily be converted to a water bath (or for MC10 only to an autoclave for media
sterilization in glassware).
Safety information
Regardless of the listed safety notes, all locally applicable regulations must be observed.
1) This product may only be operated in a secure, protected network with trustworthy clients.
2) MEDIACLAVE may only be used by properly trained personnel in a manner specified by
INTEGRA Biosciences.
3) In error case the instrument must not be used, e.g. if the pressure value is not displayed or above
1.7 bar or hot steam is released from the safety valve. There is the risk of burns or explosion.
The instrument must be immediately switched off and separated from electricity supply. Stay
away from the device.
4) Observe the hazard warnings on the device. Caution is required when opening ports or the vessel
lid (potential risk of delay in boiling). Always wear safety goggles and oven gloves.
5) The hoses may get hot. Do not touch the hoses during operation.
6) Servicing work and repairs may only be performed by INTEGRA Biosciences or an authorized
after-sales service member.
7) It is mandatory that a service is carried out at least once a year or after 1000 sterilization cycles
(whatever is reached first).
Getting started
Install the instrument on a horizontal surface according to the IQ (PN 136951) and OQ (PN
136952) documents.
a. Safety cover
b. Safety valve
c. Dispense port
d. Vessel lid
e. Temperature probe for media
f. Adding port
g. Safety cover lock
h. Operating panel
i. Main switch
j. USB port
k. Printer (optional)
Switch on/off:
Press the main switch.
Switch on the device. In the MAIN MENU, three options are accessible:
SELECT PROGRAM: To define and execute a program.
MAINTENANCE: To drain or fill the vessel, automatically clean the
device and perform the safety valve tests.
SYSTEM PARAMETER: To configure general device parameters,
make a backup to USB, etc..
k
d
e
f
g
b
h
i
j

Other manuals for Integra MEDIACLAVE 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Integra MEDIACLAVE 10 and is the answer not in the manual?

Integra MEDIACLAVE 10 Specifications

General IconGeneral
BrandIntegra
ModelMEDIACLAVE 10
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals