EasyManua.ls Logo

Intel P4000 - 11-2010 SPECIFICATION - Page 8

Intel P4000 - 11-2010 SPECIFICATION
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Summary Tables of Changes
8
Specification Update
AAZ
Errata (Sheet 1 of 5)
Number
Steppings
Status ERRATA
C-2 K-0
AAZ1 X X No Fix The Processor May Report a #TS Instead of a #GP Fault
AAZ2 X X No Fix
REP MOVS/STOS Executing with Fast Strings Enabled and
Crossing Page Boundaries with Inconsistent Memory Types May
Use an Incorrect Data Size or Lead to Memory-Ordering
Violations
AAZ3 X X No Fix
Code Segment Limit/Canonical Faults on RSM May Be Serviced
before Higher Priority Interrupts/Exceptions and May Push the
Wrong Address onto the Stack
AAZ4 X X No Fix
Performance Monitor SSE Retired Instructions May Return
Incorrect Values
AAZ5 X X No Fix
Premature Execution of a Load Operation Prior to Exception
Handler Invocation
AAZ6 X X No Fix MOV To/From Debug Registers Causes Debug Exception
AAZ7 X X No Fix
Incorrect Address Computed For Last Byte of FXSAVE/FXRSTOR
Image Leads to Partial Memory Update
AAZ8 X X No Fix
Values for LBR/BTS/BTM Will Be Incorrect after an Exit from
SMM
AAZ9 X X No Fix
Single Step Interrupts with Floating Point Exception Pending
May Be Mishandled
AAZ10 X X No Fix
Fault on ENTER Instruction May Result in Unexpected Values on
Stack Frame
AAZ11 X X No Fix
IRET under Certain Conditions May Cause an Unexpected
Alignment Check Exception
AAZ12 X X No Fix
General Protection Fault (#GP) for Instructions Greater than 15
Bytes May Be Preempted
AAZ13 X X No Fix
General Protection (#GP) Fault May Not Be Signaled on Data
Segment Limit Violation above 4-G Limit
AAZ14 X X No Fix
LBR, BTS, BTM May Report a Wrong Address When an
Exception/Interrupt Occurs in 64-bit Mode
AAZ15 X X No Fix
MONITOR or CLFLUSH on the Local XAPIC's Address Space
Results in Hang
AAZ16 X X No Fix
Corruption of CS Segment Register during RSM While
Transitioning from Real Mode to Protected Mode
AAZ17 X X No Fix
Performance Monitoring Events for Read Miss to Level 3 Cache
Fill Occupancy Counter May Be Incorrect
AAZ18 X X No Fix
A VM Exit on MWAIT May Incorrectly Report the Monitoring
Hardware as Armed
AAZ19 X X No Fix
Performance Monitor Event SEGMENT_REG_LOADS Counts
Inaccurately
AAZ20 X X No Fix
#GP on Segment Selector Descriptor That Straddles Canonical
Boundary May Not Provide Correct Exception Error Code

Related product manuals