Platform Management OverviewIntel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
54 Revision 1.1
Intel order number G34153-003
the BMC without a watchdog-generated reset occurring for a period of > 30 minutes. The BMC
FW logs a SEL event indicating that a watchdog-generated BMC reset (either soft or hard reset)
has occurred. This event may be logged after the actual reset has occurred. Refer sensor
section for details for the related sensor definition. The BMC will also indicate a degraded
system status on the Front Panel Status LED after an BMC HW reset or FW stack reset. This
state (which follows the state of the associated sensor) will be cleared upon system reset or (AC
or DC) power cycle.
Note: A reset of the BMC may result in the following system degradations that will require a
system reset or power cycle to correct:
1. Timeout value for the rotation period can be set using this parameter; potentially incorrect
ACPI Power State reported by the BMC.
2. Reversion of temporary test modes for the BMC (for example, as set through Set SM Signal
command) back to normal operational modes.
3. FP status LED and DIMM fault LEDs may not reflect BIOS detected errors.
4.3 Sensor Monitoring
4.3.1 Overview
The BMC monitors system hardware and reports system health. The information gathered from
physical sensors is translated into IPMI sensors as part of the “IPMI Sensor Model”. The BMC
also reports various system state changes by maintaining virtual sensors that are not
specifically tied to physical hardware. This section describes the BMC sensors as well as
describing how specific sensor types are modeled. Unless otherwise specified, the term
“sensor” refers to the IPMI sensor-model definition of a sensor.
4.3.2 Core Sensor List for EPSD Platforms Based on Intel
®
Xeon
®
Processor
E5 4600/2600/2400/1600/1400 Product Families
Specific server boards may only implement a sub-set of sensors and/or may include additional
sensors. The system-specific details of supported sensors and events are described in the
Appendix of this document. The actual sensor name associated with a sensor number may vary
between server boards or systems.
Sensor Type Codes
Sensor table given below lists the sensor identification numbers and information regarding the
sensor type, name, supported thresholds, assertion and de-assertion information, and a brief
description of the sensor purpose. Refer to the Intelligent Platform Management Interface
Specification, Version 2.0 for sensor and event/reading-type table information.
Sensor Type
The sensor type references the values in the Sensor Type Codes table in the Intelligent
Platform Management Interface Specification Second Generation v2.0. It provides a
context to interpret the sensor.
Event/Reading Type
The event/reading type references values from the Event/Reading Type Code Ranges
and the Generic Event/Reading Type Code tables in the Intelligent Platform
Management Interface Specification Second Generation v2.0. Digital sensors are
specific type of discrete sensors that only have two states.
Event Thresholds/Triggers

Table of Contents

Other manuals for Intel W2600CR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel W2600CR and is the answer not in the manual?

Intel W2600CR Specifications

General IconGeneral
BrandIntel
ModelW2600CR
CategoryMotherboard
LanguageEnglish

Related product manuals