EasyManua.ls Logo

Intelbras AMT 8000 - Page 34

Intelbras AMT 8000
163 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
»
When the alarm center or partition receives the command to activate and
any of the zones are open, a fault/error will be generated (long beep on the
keyboards) and it will only be possible to activate the alarm center when all
zones are closed in the case of a full or non-partitioned system, or in the case
of partitioned systems with the zones of the respective closed partitions. To
activate the alarm center with open zones, refer to section
General settings 1.
Activating/Deactivating on non-partitioned systems
Activation in
Full
mode
To enable the system completely, enter a valid password on the XAT 8000 keyboard,
for example, the master password. To know if the alarm center is activated just slide
the cover of the keyboard and display the message, if the alarm center is activated
will be displayed the message:
Alarm activated
, otherwise
Alarm deactivated
will
be displayed.
Activation by a key
If the
One Key Activation
function is enabled (see section
General settings 1
),
keeping the active key pressed until the keyboard beeps ( + /- 3 seconds) will
activate the system in
Full
mode. Exit time will be initiated to exit the protected
area. At the end of the exit time, the system will be activated in
Full
mode (all
partitions). This procedure does not allow you to deactivate the system.
Note: If a common keyboard is used, all partitions will be activated in the case of a
partitioned alarm center. In the case of a keyboard with permissions for partitions,
only the partition on which this keyboard has permission will be activated.
Disabling the system
To deactivate the system enter a valid password, for example, the master password.
After entering the password, the alarm center will be completely disabled and the
Alarm Disabled
information will be displayed.
The zones, which must be passed until the keyboard is reached, must be
programmed as entry timers or as followers so that the alarm not to be triggered
immediately when the keyboard access path is violated/accessed. After entering
the protected area by an entry time zone, the entry time will start and the user
must enter a valid password on the keyboard before the time limit ends, to avoid
triggering the alarm and reporting the corresponding events. Refer to the section
Zones functions
to set as timed.