6.3. Wireless sensor functions
Wireless sensor testing
This function will test the sensors and after the following command is entered,
when the sensors are activated, the sirens added to the partition in which the
sensors are congured or the siren 01 or less registered value, in the case of
non-partitioned systems, will be activated, indicating that the sensor is operating
correctly.
To program this function, type:
+
52
+
Enter Enter
For open type sensors, the siren will be activated on opening and closing of the
sensor and for infrared sensors, it will be activated on each activation while the
command is active.
To exit wireless sensor test mode, press the
Exit
key, enter another programming
sequence or enter the programmer password to exit programming mode.
Device Address Identication
To identify in which position the device is registered in the alarm center it is
necessary to have at least 1 XAT 8000 keyboard registered to system with the
display on.
To perform the address identication test, press and release the sync button on the
desired device and wait for the 2 conrmation beeps on the keyboard. Soon after, a
message will be displayed with the device position and also the partition, to which
it belongs in case of partitioned systems.
Example of a test with sensor 01 of non-partitioned alarm center:
» 1 line of the display: Localized P00 message will be displayed
» 2 line of the display: Sensor 01 message will be displayed
Note: For partitioned system you will see P00 for common partition or P01 to P16
according to which partition the device belongs.
Adjusting Wireless Infrared Sensors
Wireless infrared sensors registered in the AMT 8000 alarm center can be
customized to operate in the best way, as described below: