After the command, using the keys on the keyboard, enable option
1
(marking
1) and press the
Enter
key to conrm.
» Programming the network mask
Enter + 8130 + Enter
After the command, enter the network mask number and press the
Enter
key
to conrm.
» Programming the gateway
Enter + 8140 + Enter
After the command, enter the network gateway number and press the
Enter
key to conrm.
» Programming DNS Servers for Ethernet
Enter + 815 + S + Enter
, where S = 1 or 2 (Server 1 or Server 2)
After the command, enter the DNS1 server number and press the
Enter
key to
conrm.
» Program the Heartbeat Ethernet interval (link test)
Enter + 816 + TTM + Enter
, where TTM = time interval ranging from 000 to 255
minutes (factory default:
5 minutes
)
» Exit programming mode with installer password
Installer password (factory standard:
9090
)
» Check connection to IP Receiver service
Press the
Menu
key, navigate through the arrow keys, access the
Connections
option and check if the marking for the
Eth: IP1
and/or
IP2
is enabled. If so, the
unit is connected via Ethernet with the IP receiver software through the IPs that
have been enabled.
Monitoring via GPRS
Alarm center can report events via GPRS channel - required XAG 8000 module, for
monitoring companies, being the send of events to monitoring companies will use
the GPRS channel to send to IP addresses, as well as the Ethernet connection. The
commands to be programmed are as follows:
Note:
after inserting each command and conrming with the
Enter
key, two quick
beeps must be heard, indicating that the programming was accepted, otherwise,