» Entering the programming mode with the installer password
Enter + installer password
(factory default:
9090
)
» Schedule monitoring account
Enter + 15 + PP + Enter
, where PP = partition from 01 to 16
After the command, enter the 4-digit monitoring account number and press the
Enter
key to conrm.
» Programming the reporting mode
Enter + 17 + 4 + 0 + 0 + Enter
» Program communication priority (GPRS only)
Enter + 19 + 1 + Enter
» Program target IP
Enter + 801 + I + Enter
, where I = 1 or 2 (target IP 1 or target IP 2)
After the command, enter the IP number of the monitoring company 1 (example:
192.168.001.100) and press the
Enter
key to conrm.
» Program IP network communication port
Port 1 = Enter + 802 + 1 + Port number with 4 digits + Enter
Port 2 = Enter + 802 + 2 + Port number with 4 digits + Enter
» Program target domain name (DNS)
If you don't want to use DNS, go to the next command, otherwise type:
Enter + 803 + D + Enter
, where D = 1 or 2 (DNS 1 or DNS 2).
After the command, type the DNS domain name and press the
Enter
key to
conrm.
» Program monitoring options via IP
Enter + 830 + Enter
After the command, using the keys on the keyboard, enable the desired option
from 1 to 4, where:
» 1: enables the sending of events to the monitoring company 1.
» 2: enables the sending of events to the monitoring company 2.
» 3: enables the domain name (DNS) of the monitoring company 1.
» 4: enables the domain name (DNS) of the monitoring company 2 and press the
Enter
key to conrm.