Use the keys on the keyboard to dene the zone mode, so that the reference
numbers, which you wish to have the zone with the given mode, remain marked
and the zones without the mode remain unchecked, then conrm with the
Enter
key.
Note:
The settings made on a sensor are only effective after the tamper has been
activated, triggered or the respective synchronism button has been pressed quickly.
Automatic zone cancellation
This function will temporarily cancel a zone if it res the programmed number of
times within a same activation. For example, with the number of res set to 4, the
fourth time a sensor trips while the system is activated, the corresponding zone will
be canceled and the corresponding event sent to the monitoring company.
When the system is deactivated, the zone will return to normal operation. If the
number of trips is programmed as 0 the function will be disabled.
To program this function, type:
+
53 Number of trips
+
Enter
+
Enter
0 to 9
To edit/view the programmed value, type:
53
+
Enter Enter
+
After changing the congured value, press the
Enter
key. If you only want to view
the setting, press the
Back/Exit
key that no programming will be changed.
6.11. Programming the alarm center partitioning
Enable partitioning
To enable alarm center partitioning (the center can have up to 16 partitions with
independent activation/deactivation and event reporting), it must be programmed:
510
+
Enter Enter
+
Use the keyboard key
1
to enable the center partitioning, so that the number 1
remains checked to enable and unchecked to disable partitioning and then conrm
with the
Enter
key. If you only want to view the setting, press the
Back/Exit
key that
no programming will be changed.