97
After changing the congured value, press the
Enter
key. If you only want to view
the setting, press the
Exit
key and no programming will be changed.
Note:
in the above command for non-partitioned alarm center, use Partition = 01.
6.16. Telephony and Monitoring Settings
AMT 8000 alarm center was specially developed to be monitored remotely, that is,
a contractor can monitor several events in real time, for example:
» System activation and deactivation.
» Lack of power.
» Violation of the system (triggering).
» Fault in the phone line.
» Violation of the sensors (tamper).
» Siren failure.
When an event occurs, the alarm center will contact the monitoring company and
will transmit via DTMF or IP (Ethernet, Wi-Fi or GPRS) the event occurred (internal
buffer for 512 events).
Note:
to have the monitoring via phone line and GPRS it is necessary that the
FXO
8000 and XAG 8000
expander modules respectively are added to the alarm center.
Contact-ID Events
The alarm center leaves the factory with all events enabled and with the standard
Contact-ID code corresponding to these events.
In the standard conguration of the programmable Contact-ID protocol the
following events will be sent with the most common event codes. This will eliminate
the need to register new events in the monitoring software, but the information
will not be as full as in the complete Contact-ID protocol. See below for a list of
Contact-ID events.
Event Standard code
Medical emergency 100
Fire alarm 110
Panic 120
Activation and deactivation under duress 121
Silent panic 122
Zone triggering/Zone restoration 130
24 hour zone triggering 133
Silent triggering 146
AC mains failure/AC mains restoration 301