EasyManua.ls Logo

Intelbras AMT 8000 - Page 99

Intelbras AMT 8000
163 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
99
» Sensor communication failure in zone 12: event
147
(factory standard) and
with user/zone being
012
.
» Sensor reset in zone 64: event
130
(factory standard) and with user/zone being
064
.
» Sensor tamper in zone 05: event
383
(factory standard) and with user/zone
being
005
.
» Keyboard tamper registered at address 01: event
145
(factory standard)
and with user/zone being
201
.
» Siren tamper registered at address 09: event
145
(factory standard) and
with user/zone being
309
.
» Keyboard communication failure registered at address 01: event
381
(factory standard) and with user/zone being
201
.
As can be seen in the following commands, according to the registered Contact-ID
code, the event may be blocked if congured as 000 (will not be sent to the IP
Receiver). The registration of the Contact-ID code can be done according to the
available options of Contact-ID code, or even, when registering FFF will cause the
option that is registered with this value to send to the monitoring company the
default Contact-ID code.
The following tables show the events and the respective standard Contact-ID
codes:
Events of the opening type
Zone triggering
Zone no. Event Contact-ID Code
01 to 64 Zone triggering 130
The commands relating to the Contact-ID, more specically the Programmable
Contact-ID, the communication protocol must be set to Programmable Contact-
ID, otherwise events will be sent with the standard Contact-ID. Refer to the topic
Reporting
mode, in the part explaining the Phone Protocol 1/2.
Use the table above to perform the
Contact-ID
event change command for zone
triggering described below:
901
+
Enter Enter
+ +
Zone N°
01 to 64

Other manuals for Intelbras AMT 8000