Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 187
The entry timers can be programmed from 0 to 255 seconds. 0 means the timer
is not engaged and the alarm is activated immediately when entering the armed
premises. 255 and more means the time is infinite.
Note: If zones are assigned to more then one area, the longest entry and exit
time is used. See “4 Zones and areason page 171.
4.2.n.3.1 Entry time 1
4.2.n.3.2 Entry time 2
Configure entry timers for entry/exit 1 and entry/exit 2 zone types. See “4.2.n.3
Entry timeon page 186 for details on entry timer programming.
4.2.n.3.3 PS Entry time 1
4.2.n.3.4 PS Entry time 2
Configure part set entry timers for entry/exit 1 and entry/exit 2 zone types.
Part set entry timers are configured the same way as full set entry timers. See
“4.2.n.3 Entry timeon page 186 for details on entry timer programming.
4.2.n.4 Other timers
1>Warning time
1
The menu groups additional area timers. See submenus below for details.
4.2.n.4.1 Warning time
1 Warning time
> <
Warning time is a period of time during which the automatic set procedure can be
postponed. After the warning time expires, the system is set.
The set postponing must be allowed in “4.2.n.5.2 Set retryon page 188.
The warning timer can be programmed from 1 to 15 minutes.
4.2.n.4.2 Prealarm time
2 Prealarm time
> <
Every area has its own prealarm timer. When an alarm is triggered, it only
generates a local alarm, and the prealarm timer is started. If the local alarm is not
acknowledged during the prealarm time, the alarm is reported.
Note: The entry zone must have activated option “4.1.n.6.14 Extend EE
described on page 176.
Use the PreAlarm time screen to set the prealarm time for the area. Each area
can be programmed with one prealarm time.
The prealarm timers can be programmed from 0 to 255 seconds.

Table of Contents

Other manuals for Interlogix ATS1500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS1500A-IP-MM and is the answer not in the manual?

Interlogix ATS1500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS1500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals