Chapter 3: System functions
80 Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
Tests and diagnostics
The Advisor Advanced system provides a range of test features. Most of them
are accessible from “1.2 Test menuon page 121.
Input and detector tests
To test single inputs or detectors, use “1.2.1 Input testson page 121. A single
input state can be checked in “1.2.1.7 Zone kOhmon page 123.
To verify wireless input status, use “1.2.1.3 RF RSSI teston page 122 and
“1.2.1.4 RF diagnosticson page 122.
Wireless PIR camera range can also be verified in “1.2.1.5 Cam range teston
page 123.
If the detector has an internal test functionality, use “1.2.1.8 Detector teston
page 124 to configure an autotest, or to run it manually.
Test shock sensors via “1.2.2 ShockSens teston page 125.
Outputs
Test outputs or verify their state using the “1.2.3 Outs&triggers” menu on page
125.
Walk test
Walk test is a working system test performed by a user or installer. To pass the
test, the user or installer has to walk past detectors to activate these. The
intention is to test the functionality of the security system.
The zone passes the test when switching its state from normal to active, and
then from active to normal. In walk test mode each zone state change is
signalled by the keypad buzzer or an internal bell.
The menu “1.2.5 Walk teston page 127 allows you to run the test manually
(engineer walk test), as well as define conditions when the user has to perform
the walk test, including a required walk test before setting an area (user walk
test).
The menu also allows you to run a walk test for a single zone, as well as a
general walk test, which is required by a central station operator to verify all
alarm system features, including set and unset, entry and exit, tampers, etc.
Engineer walk test
The walk test initiated and executed by the service engineer.
The walk test applies to all zones that have option “4.1.n.6.11 Engineer walk test
on page 175 enabled.

Table of Contents

Other manuals for Interlogix ATS1500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS1500A-IP-MM and is the answer not in the manual?

Interlogix ATS1500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS1500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals