Chapter 2: Installation
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 33
[2] When using ATS624 relay card with the ATS1810 expander attached, expander output 8
state is inverted.
[3] Inputs 17 to 32 of Expander 15 cannot be used.
[4] You cannot connect more than 15 expanders and 16 keypads to one system databus. To
connect more bus devices to a panel, it is necessary to install ATS670 second RS485 LAN
extension module. See also “Two system databuses” on page 23.
Doors
There are two types of doors, intelligent and standard. Standard doors (1 to 16)
are handled by the control panel. Keypads or readers 1 to 32 connected to the
Advisor Advanced control panel system databuses are used for simple access
control functions.
Intelligent doors (17 to 64) are controlled by door controllers. Keypads or readers
connected to local databuses of door controllers are named “door controller
readers (DC readers)” and are used for advanced access control functions.
See “Doors” on page 68 for more details.
Table 4 below shows the door, zone and output numbering for door controllers.
Table 4: Door, zone, and output numbering in door controllers
Door controller
Doors
Zones
1
17–20
17–48
2
21–24
49–80
3
25–28
81–112
4
29–32
113–144
5
33–36
145–176
6
37–40
177–208
7
41–44
209–240
8
45–48
241–272
9
49–52
273–304
10
53–56
305–336
11
57–60
337–368
12
61–64
369–400