Chapter 5: Menu reference
186 Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
Use the Area name screen to enter or edit the area name. The area name can
contain up to 16 characters.
4.2.n.2 Exit time
2 Exit time 1
> <
Every area has its own exit timers. Exit timers allow users that set an area, to
leave the premises without generating an alarm (using access or entry/exit
zones). Only after the exit timers have expired can an alarm occur.
Each area can be programmed with two exit times, one for entry/exit 1 zone type,
another one for entry/exit 2 zone. Select an appropriate timer and set the time.
The exit timers can be programmed from 0 to 255 seconds. 0 means the timer is
not engaged and the area is set immediately. 255 means the timer remains
active and requires an exit terminator (see “4.1.n.2 Zone typeon page 172) or a
zone with the final door option (see “4.1.n.6.15 Final dooron page 176) to
complete.
Note: If zones are assigned to more then one area, the longest exit time is used.
See “4 Zones and areason page 171.
4.2.n.2.1 Exit time 1
4.2.n.2.2 Exit time 2
Configure exit timers for entry/exit 1 and entry/exit 2 zone types. See “4.2.n.2 Exit
timeabove for details on exit timer programming.
4.2.n.2.3 PS Exit time 1
4.2.n.2.4 PS Exit time 2
Configure part set exit timers for entry/exit 1 and entry/exit 2 zone types.
Part set exit timers are configured the same way as full set exit timers. See
“4.2.n.2 Exit timeabove for details on exit timer programming.
4.2.n.3 Entry time
3 Entry time 1
> <
Every area has its own entry timer. When entering the premises via an entry/exit
zone, the entry time starts. A user can unset the area while the entry time is
running without generating an alarm provided only entry/exit zones or access
zones are activated.
Note: The entry time can be extended for particular entry zones. See “4.2.n.4.2
Prealarm timeon page 187 for more details.
Each area can be programmed with two entry times, one for entry/exit 1 zone
type, another one for entry/exit 2 zone. Select an appropriate timer and set the
time.

Table of Contents

Other manuals for Interlogix ATS4500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS4500A-IP-MM and is the answer not in the manual?

Interlogix ATS4500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS4500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals