Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 149
AG symbolic: The same as symbolic, but for area groups.
See Advisor Advanced User Guide for more information on area selection.
2.2.1.n.3.16 LCD backlight
16 Status ind.
>Always on<
LCD backlight option defines when the keypad display backlight is lit. There are
the following options available:
Always on: LCD backlight never switches off.
Normal: LCD backlight switches off after the particular idle time.
Excl. entry: LCD backlight is off during the entry time, until a key is pressed.
Note: The backlight timeout depends on the particular keypad firmware.
2.2.1.n.3.17 ACK on keypad
1>Rkp 1
2 Rkp 2
The ACK on keypad option allows you to select an additional LCD keypad that
displays an acknowledgement prompt after the system is unset using the
selected non-LCD keypad or reader.
Note: This option is only available for non-LCD keypads and card readers.
See also “4.1.n.6.26 ACK on keypadon page 178 for more details.
2.2.1.n.3.18 EE 1 buzzer
18 EE 1 buzzer
>Yes<
If the option is set to Yes, the buzzer of the selected keypad is active during
entry/exit time 1.
See “2. Entry/Exit 1on page 45 for more details.
2.2.1.n.3.19 EE 2 buzzer
19 EE 2 buzzer
>Yes<
If the option is set to Yes, the buzzer of the selected keypad is active during
entry/exit time 2.
See “18. Entry/Exit 2on page 47 for more details.
2.2.1.n.3.20 1+3 keys
20 1+3 keys
>Yes<
If the option is set to Yes, the combination of 1 and 3 keys allows you to raise a
panic alarm.