Chapter 8: Regulations
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 309
For SES Grade 3 is not allowed to program GPRS communication as primary
CS, it is only allowed in Grade 2.
The table below indicates the required polling intervals for SES Grade 2 and
Grade 3.
Primary CS (IP)
AÜA-B25
AÜA-B5
AÜA-S180
AÜA-S20
25 h
5 h
180 sec
20 sec
Back-up CS
(GPRS)
AÜA-B25
25 h
2
2, 3
2, 3
2, 3
AÜA-B5
5 h
2
2, 3
2, 3
2, 3
* 2, 3: EN-CH Grade of the system
The following options must be set:
Standard and
category
Required
polling
interval
Comm. path and
dialler
Option
Required
value
SES CHD.07 (V3 / 01.01.2011)
AÜA-B25
25 h
IP built-in, or GPRS
via ATS7310
9.1.n.8.3.2 Heartbeat time
24
AÜA-B5
5 h
IP built-in, or GPRS
via ATS7310
9.1.n.8.3.2 Heartbeat time
4
AÜA-S180
180 s
IP built-in, or GPRS
via ATS7310
9.1.n.8.3.2 Heartbeat time
00:02'30
AÜA-S20
20 s
IP built-in
9.1.n.8.3.2 Heartbeat time
00:00'10
SBSC policy
Larmklass 1
Required settings are all EN 50131 Grade 2 settings with the following
modifications:
4.2.n.5.1 Entry alarms: Instant
8.7.6.9 Reporting delayed: No
See also “EN 50131 Grade 2on page 302.
Larmklass 2
Required settings are all EN 50131 Grade 3 settings with the following
modifications:
4.2.n.5.1 Entry alarms: Instant
8.7.6.9 Reporting delayed: No
See also “EN 50131 Grade 3on page 303.