Chapter 5: Menu reference 
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual  177 
4.1.n.6.18 Key unset 
 
If the Key unset option is set to Yes, the zone is a key switch that unsets an area. 
4.1.n.6.19 Technical full set 
 
If the Technical full set option is set to No, the technical alarms in this zone are 
disabled when the area is fully set. 
4.1.n.6.20 Technical unset 
 
If the Technical unset option is set to No, the technical alarms in this zone are 
disabled when the area is unset. 
4.1.n.6.21 Technical part set 
 
If the Technical part set option is set to No, the technical alarms in this zone are 
disabled when the area is partially set. 
4.1.n.6.22 Keypad LCD 
 
If the Keypad LCD option is set to Yes, when the zone activates, the zone name 
is displayed on the keypad LCD on all keypads, related to the area. 
4.1.n.6.23 Log 
 
The Log option determines whether the zone event is recorded in the system log. 
4.1.n.6.24 CS report 
 
The CS report option determines whether the zone event is reported to the 
central station.