Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 183
4.1.n.7.1 Pulse count
1>Pulse count
0
Set the number of pulses within a time window that will activate the zone.
The following values are applicable:
1 to 9: number of pulses within 30 seconds that activates the zone. Only 1
count per second is taken into account.
0: the counter functionality is disabled.
4.1.n.7.2 Gross level
2>Gross level
0
Use the Gross level option to set the level for a single pulse that activates the
zone. The following values are applicable:
1 to 9: Gross attack level where 1 means high sensitivity, and 9 means low
sensitivity
0: Gross level is disabled
Gross level can be checked in menu “1.2.2 ShockSens test” (see page 125).
Wireless sensor options
4.1.n.7 RF details
1>Sensor ID
10EBA9E
The RF details menu allows you to program a wireless device manually, or
remove it from the wireless expander.
Note: This menu is only available for a wireless expander ATS1235 with
firmware version 1.13 or newer, which is online.
4.1.n.7.1 Sensor ID
1>Sensor ID
10EBA9E
The screen allows you to view the sensor ID.
Note: First two digits of the sensor identifier also define the sensor type. See
Table 26 on page 184.