Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 207
5.1.n.3.5.7 Disable Duress
7 Disable Duress
>No<
This option is used to disable duress codes from functioning. If set to Yes, no
duress function is available at this door.
5.1.n.6.1.2 Second zone
0>No
17 Zone 17
The door controller allows the system to monitor two door contacts for a single
intelligent door. Select a second zone with door contact for the selected door. If
there is only one door contact, select No.
See also “5.1.n.6.1.1 Door zoneon page 199.
5.1.n.6.1.3 DOTL zone
0>Not used
17 Zone 17
Specify the zone that reports the DOTL (door open to long) alarm condition for
the selected door.
Note: DOTL reporting must be enabled in Shunt options. See “5.1.n.6.5.5 DOTL
on page 210.
5.1.n.6.2 Door unlocked
1>Lock when CL
No
The menu contains various options for the selected door unlocking process.
5.1.n.6.2.1 Until closed
1 Until closed
>No<
This option determines when the door will re-lock using the re-lock delay.
Yes: The door lock will not re-lock until the door is closed. This is used where
the lock mechanism, when locked, will stop the door closing.
No: The door lock will re-lock (after the unlock time has expired, etc.)
regardless of the door being open or closed.
5.1.n.6.2.2 Until opened
2 Until opened
>No<
For security reasons, it is possible for the door to re-lock at the moment it opens.
The door stays unlocked until opened, and the door relay is deactivated after the
door opens.